Specification - Extended HL7 CDA® R2 IG: C-CDA Templates for Clinical Notes DSTU Release 2.1 - US Realm
Document Description extended per extended per TSC tracker 12437, again with 14128 and jira.hl7.org/browse/TSC-38
Existing WordingThe value set for status of Result Observation (V3) [Result Status urn:oid:2.16.840.1.113883.11.20.9.39 STATIC] is broadly incompatible with the FHIR US Core value sets for Observation status (http://hl7.org/fhir/valueset-observation-status.html) and DiagnosticReport status (http://hl7.org/fhir/valueset-diagnostic-report-status.html). Here are the values for reference: (C-CDA) Result Status urn:oid:2.16.840.1.113883.11.20.9.39: aborted active cancelled completed held suspended (FHIR) Observation Status: registered preliminary final amended corrected cancelled entered-in-error unknown (FHIR) DiagnosticReport Status: registered partial preliminary final amended corrected appended cancelled entered-in-error unknown
Proposed WordingDetermined approved alignment between FHIR and C-CDA and apply changes to the Result Status urn:oid:2.16.840.1.113883.11.20.9.39 value set as appropriate.