Specification - Extended HL7 CDA® R2 Implementation Guide: C-CDA Templates for Clinical Notes Companion Guide, Release 2 STU - US Realm
Document Description extended per TSC vote https://confluence.hl7.org/x/Ujb9Aw
Existing Wording(Vocab issue) Table 9 of the Companion Guide recommends the LOINC codes 11502-2 for Laboratory Narrative notes and 11526-1 for Pathology Narrative notes. However, these codes aren't actually included in the Note Types value set (urn:oid:2.16.840.1.113883.11.20.9.68) as required by the Notes Section and Note Activity templates in Appendix A. Likewise, although no specific LOINC code is recommended for Imaging Narrative notes, the value set doesn't include any codes from the value set recommended for imaging notes in Table 8 (urn:oid:1.3.6.1.4.1.12009.10.2.5).
Proposed Wording[Add these LOINC codes to the value set.]