Type:
Change Request
-
Resolution: Persuasive with Modification
-
Priority:
Medium
-
US Core (FHIR)
-
STU3
-
Structured Documents
-
Device [deprecated]
-
Profiles and Extensions
-
SD
-
-
Ioana Singureanu/Hans Buitendijk: 48-0-5
-
Enhancement
-
Compatible, substantive
Comment:
The following us-core-device "must support" data elements are missing:
+ Device.udiCarrier: "S", [1..1] for implantable devices
+ Device.udiCarrrier.deviceIdentifier - is mandatory, therefore the parent element has to be mandatory and it requires "S", [1..1]
+ Device.udiCarrier.HRFcarrier OR Device.udiCarrier.AIDCcarrier MAY be supported
+ Device.distictIdentifier "S" [0..1] SHALL be supported for HCT/P regulated as a device, the distinct identification code required by 21 CFR 1271.290(c).
+ Device.manufactureDate "S", [1..1]
+ Device.expirationDate "S", [1..1]
+ Device.lotNumber "S". [0..1] - SHALL be supported if the Production Identifier specifies a lot number
+ Device.serialNumber "S", [0..1] - SHALL be supported if the Production Identifier specifies a serial number
Summary:
Add missing "must support" data elements to support the MU2015 and CCDS requirements: (A) Device Identifier; and (B) The following identifiers that compose the Production Identifier: (1) The lot or batch within which a device was manufactured; (2) The serial number of a specific device; (3) The expiration date of a specific device; (4) The date a specific device was manufactured; and (5) For an HCT/P regulated as a device, the distinct identification code required by 21 CFR 1271.290(c)."
- is voted on by
-
BALLOT-7455 Negative - Greg Staudenmaier : 2019-Jan-FHIR US CORE R1
- Balloted