Type:
Change Request
-
Resolution: Not Persuasive with Modification
-
Priority:
Medium
-
US Minimal Common Oncology Data Elements (mCODE) (FHIR)
-
STU3
-
Clinical Interoperability Council
-
Profiles
-
BodyHeight
-
-
MayTerry/Richard Esmond: 14-0-0
-
Correction
-
Compatible, substantive
Existing Wording: component 0..0
Comment:
Profile description says "this profile builds on observation-bodyheight". If this is intended to say that the mCode BodyHeight profile is conformant to observation-bodyheight, then this is incorrect. The "base" BodyHeight profile http://hl7.org/fhir/R4/bodyheight.html has Observation.component 0..* as MustSupport, so an implementer is allowed to send this value; an implementer of mCode would reject a message if it contained Observation.component, breaking conformance.
We have found two such examples, but there may be many more that need to be reviewed.
Summary:
Removal of component element from mCode BodyHeight profile breaks conformance with base BodyHeight profile.
- is voted on by
-
BALLOT-10748 Negative - Ron G. Parker : 2019-Sep-FHIR IG MCODE R1
- Balloted