Type:
Change Request
-
Resolution: Not Persuasive
-
Priority:
Highest
-
US Core (FHIR)
-
3.1.1
-
Cross-Group Projects
-
(NA)
-
18.111.1
-
-
Brett Marquard/Gay Dolin: 9-0-3
HL7 Core vitals provides redundant and inconsistent advice on constructing panels, specifying the use of Observation.component under #7 and the use of Observation.related under #9. While #9 is out of date (R4 uses "hasMember" rather than the STU3 "related"), the guidance provided for Observation suggests that #9 is correct and #7 is incorrect for Vital Signs. (Viz., "Observation.component is used for any supporting result that cannot reasonably be interpreted and used outside the scope of the Observation it is a component of.")
Ramifications of using the incorrect #7 pattern include a collision between appropriate vitals units and units needed for O2 supplementation, a reason for which US Core departs from this specification.
US Core repeats the incorrect #7 guidance from HL7 Core, enforcing the addition of L/min to vitals units\. We should use member\.
Existing Wording:
3. Component results
Proposed Wording:
3. Member results
(Comment 69 - imported by: Jean Duteau)
- is voted on by
-
BALLOT-14972 Negative - Vannak Kann : 2021-Jan-FHIR US CORE R1 STU2 STU
- Balloted
- relates to
-
FHIR-30772 Don't follow core guidance on heart rate
-
- Applied
-