Type:
Change Request
-
Resolution: Persuasive with Modification
-
Priority:
Highest
-
US Core (FHIR)
-
3.1.1
-
Cross-Group Projects
-
(NA)
-
-
Correction
(Comment about http://hl7.org/fhir/R4/observation-vitalsigns.html#vitals-table)
Device
Such an observation is meaningless in isolation and should be a component, if it can't be accommodated with CIMI extension observation-deviceCode or with Observation.method.
Make temperature device a method, component, or extension (VS ~ https://build.fhir.org/ig/HL7/cimi-vital-signs/ValueSet-heartRateMeasDeviceVS.html)
Site
For Site, use Observation.bodySite
Existing Wording:
8327-9 - Body temperature measurement site (oral, forehead, rectal, etc.) and 8326-1 -Type of body temperature device MAY be used as additional observations.
(Comment 2 - imported by: Jean Duteau)
- duplicates
-
FHIR-30772 Don't follow core guidance on heart rate
-
- Applied
-
- is voted on by
-
BALLOT-15139 Affirmative - Vannak Kann : 2021-Jan-FHIR US CORE R1 STU2 STU
- Balloted
- relates to
-
FHIR-30772 Don't follow core guidance on heart rate
-
- Applied
-