Perhaps just call for current published version?

XMLWordPrintableJSON

    • Type: Change Request
    • Resolution: Not Persuasive
    • Priority: Highest
    • US Da Vinci CDex (FHIR)
    • current
    • Patient Care
    • Artifacts Summary
    • 10.1.2.1
    • Hide

      Each version of an ig must reference a specific canonical version of the ig it implements in  

      CapabilityStatement.implementationGuide

      as each version is updated separately the capability may change.

      A new CDEX version would needed if want to reference a new HREX version.

      Show
      Each version of an ig must reference a specific canonical version of the ig it implements in   CapabilityStatement.implementationGuide as each version is updated separately the capability may change. A new CDEX version would needed if want to reference a new HREX version.
    • Eric Haas/Jay Lyle: 5-0-8

      This IG is likely to update at least annually. Each update will have to trigger an update to this IG. Perhaps just call for current published version?

      (Same comments apply to Data Consumer Server CapabilityStatement)

      Existing Wording:

      HL7 FHIR® US Core Implementation Guide STU3 Release 3.1.1

      (Comment 56 - imported by: Jean Duteau)

            Assignee:
            Unassigned
            Reporter:
            Thomson Kuhn
            Watchers:
            3 Start watching this issue

              Created:
              Updated:
              Resolved: