Type:
Change Request
-
Resolution: Duplicate
-
Priority:
High
-
FHIR Core (FHIR)
-
DSTU1 [deprecated]
-
Security
-
AuditEvent
-
-
Enhancement
Comments
11) Add Record Lifecycle Events x 27 (based on HL7 EHR-S FM Record Infrastructure) to SecurityEvent.Object.lifecycle code/value set:
1) Originate/retain
2) Amend/update
3) Translate
4) Attest
5) View/Access
6) Output/Report
7) Disclose
8) Transmit
9) Receive/Retain
10) De-Identify
11) Pseudonymize
12) Re-Identify
13) Extract
14) Archive
15) Restore
16) Destroy/Delete
17) Deprecate/Retract
18) Re-Activate
19) Merge
20) Unmerge
21) Link
22) Unlink
23) Place Legal Hold
24) Remove Legal Hold
25) Verify
26) Encrypt
27) Decrypt
Grahame's Comments
Some of these overlap with existing codes from IHE. How would that be handled? My preference would be to replace IHE list with this list, and map from IHE list. But not all IHE codes have an equivalent in this list. Why? Specific comment - is #1 a typo? (how can retain be an alias of originate? bizarre).
- is voted on by
-
BALLOT-219 Negative - Gary Dickinson : 2015-Jan-FHIR R1
- Balloted