Type:
Change Request
-
Resolution: Persuasive
-
Priority:
Medium
-
FHIR Core (FHIR)
-
DSTU1 [deprecated]
-
Orders & Observations
-
Observation
-
-
Eric Haas/Mark Jones: 10-0-0
-
Correction
-
Non-substantive
-
Yes
-
DSTU1 [deprecated]
Existing Wording: Generated Narrative with Details
code: Base excess in Blood by calculation (Details :
{LOINC code '11555-0' = 'Base excess in Blood by calculation', given as 'Base excess in Blood by calculation'})
value: 12.6 mmol/l (Details: http://unitsofmeasure.org code mmol/L = 'mmol/L')
interpretation: abnormal (Details :
{[http://hl7.org/fhir/v2/0078] code 'A' = 'Abnormal (applies to non-numeric results)', given as 'abnormal'})
Comment:
this one even says that A should apply to nonnumeric results and this result is numeric. Same problem with injection and use o lower case l instead of L for liters\
Why present the two variants of the normal range threshold
- is duplicated by
-
FHIR-7237 2015May core #297 - Errors in examples
-
- Published
-
- is voted on by
-
BALLOT-1019 Negative - Clement McDonald : 2015-May-FHIR R1