Type:
Change Request
-
Resolution: Persuasive with Modification
-
Priority:
Medium
-
FHIR Core (FHIR)
-
DSTU1 [deprecated]
-
Orders & Observations
-
Observation
-
-
Eric Haas /Patrick Loyd:10-4-0
-
Correction
-
Non-substantive
-
Yes
-
DSTU1 [deprecated]
Existing Wording: code: Body temperature (Details :
{SNOMED CT code '415945006' = 'Oral temperature', given as 'Oral temperature'};
{LOINC code '8310-5' = 'Body temperature', given as 'Body temperature'})
value: 39 degrees C (Details: SNOMED CT code 258710007 = 'degrees C')
Comment:
Since in the US vital signs including temo have specifically required LOINC codes think the inclusion of snomed codes as alternative will confuse - But if you do include both. A LOINC has a oral temperature too: 8331-1
Oral temperature
ONC specifies code 8310-5; for the oral temperature with discussion as to further specification as to the place the temperature was taken and lOINC has code for that and an answer list tool
- is voted on by
-
BALLOT-1020 Negative - Clement McDonald : 2015-May-FHIR R1
- Balloted