Existing Wording: The observation resource has the following aspects:
status (mandatory) - all users of observations SHALL be sure of the status of the observation
reliability - provides an estimate of the degree to which quality issues have impacted on the value of an observation
code (mandatory) - describes what was observed. This is the 'name' in the name/value pair assertion pattern used in this
resource
identifier - Unique identifier for this particular observation so it can be recognized in all contexts where it is represented
value - the actual value that was observed
related observations - Other observations that are components of this observation, or provide supporting information, context or
warnings about this observation
subject,.bodySite[x] - the patient, or group of patients, location, or device, that this observation was made on. Note that group of
patients is most often used in veterinary care. For individual patients, the location on the body may also be specified, though this
is often implicit in the Observation.code
applies[x] - The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients -
this is usually called the "physiologically relevant time.
interpretation, comments, and reference range: information to help understand the observed value
method, issued, performer - additional information about how the test was performed that may help understand the observation.
The method is often implicit in the Observation.code
Typically, an observation will have either a value or component observations, and not both.
Comment:
not bad idea to have possible. but there is no tradition for routine reporting of this as a discrete fields
- duplicates
-
FHIR-7154 2015May core #213 - Explain reliability
-
- Published
-
- is voted on by
-
BALLOT-1025 Negative - Clement McDonald : 2015-May-FHIR R1
- Balloted