Type:
Technical Correction
-
Resolution: Persuasive
-
Priority:
Medium
-
FHIR Core (FHIR)
-
DSTU1 [deprecated]
-
Terminology Infrastructure
-
ValueSet
-
6.21.7
-
-
Grahame Grieve / Eric Haas: 4-0-0
-
Non-substantive
-
DSTU1 [deprecated]
Existing Wording: •The system provides a very long display name that is unnecssary or innappropriate in the context of this value set (e.g. a display name of "Glucose [Mass/volume] in Serum or Plasma --10 PM specimen" for LOINC code 48991-4, when the value set only includes Glucose mass/vol in serum/plasma codes). As the display names get longer, this becomes more important
Proposed Wording: •The system provides a very long display name that is unnecessary or inappropriate in the context of this value set (e.g. a display name of "Glucose [Mass/volume] in Serum or Plasma --10 PM specimen" for LOINC code 48991-4, when the value set only includes Glucose mass/vol in serum/plasma codes). As the display names get longer, this becomes more important.
Comment:
"unnecessary" and "inappropriate" are not spelled correctly. Period needs to be added to the end of the paragraph.
- is voted on by
-
BALLOT-1366 Affirmative - Greg Staudenmaier : 2015-May-FHIR R1
- Closed