Type:
Change Request
-
Resolution: Persuasive
-
Priority:
High
-
FHIR Core (FHIR)
-
R5
-
FHIR Infrastructure
-
CapabilityStatement (Conformance)
-
Managing Multiple Versions
Change Management & Versioning (versions/compatibility) -
5.2.11.4.1
-
-
Rob Hausam/Christiaan Knaap: 9-0-0
-
Correction
-
Non-substantive
The documented type of the OUT Parameters is `code`, but both the example JSON and XML use `valueString`.
Furthermore, their description says "Use the major.minor version like 3.0" but based on the language in http://build.fhir.org/versions.html#versions, this should be publication.major
Associated with this, there is no specified binding for these code-type values. One might expect it to be codes from the CodeSystem http://hl7.org/fhir/FHIR-version but this only includes codes of the form publication.major.minor
- relates to
-
FHIR-26067 The FHIR-Versions CodeSystem is missing the two-digit version codes
-
- Resolved - change required
-